Eaton BR48L125SP Load Center, 125 A, 8-Pole, 4-Space, 8-Circuit, Main Lug, NEMA 1 Enclosure, Surface
PRODUCT OVERVIEW
Eaton Load Center, 120/240 V, 125 A, Number of Phases: 1, Number of Spaces: 4, Number of Poles: 8, Number of Circuits: 8, Breaker/Load Center Type: Main Lug, Interrupt Rating: 10 kA, Cable Size: 14 to 1/0 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Surface Mounting, Metal
Product Details
Breaker/ Load Center Type:Main Lug
Bus Bar Material:Aluminum
Cable Size:14 to 1/0 AWG
Current Rating:125 A
Enclosure Type:NEMA 1
Interrupt Rating:10 kA
Material:Metal
Mounting Type:Surface
Number of Circuits:8
Number of Phases:1
Number of Poles:8
Number Of Spaces:4
Voltage Rating:120/240 V
Wiring Configuration:3-Wire
View Details
|
6801088 |
Eaton BR48L125SP Load Center, 125 A, 8-Pole, 4-Space, 8-Circuit, Main Lug, NEMA 1 Enclosure, Surface |
2 |
27.99 |
/ EA |
BR48L125SP |
|
|

Eaton BRP08B200RF Load Center, 24-Pole, 200 A, 8-Space, 16-Circuit, Main Breaker, Plug-On Neutral, N
PRODUCT OVERVIEW
Eaton Load Center, 120/240 V, 200 A, Number of Phases: 1, Number of Spaces: 8, Number of Poles: 24, Number of Circuits: 16, Breaker/Load Center Type: Main Breaker, Plug-On Neutral, Bus Bar Material: Aluminum, Bus Bar Rating: 200 A, Enclosure Type: NEMA 3R, Flush, Surface Mounting
Product Details
Breaker/ Load Center Type:Main Breaker Plug-On Neutral
Bus Bar Material:Aluminum
Bus Bar Rating:200 A
Current Rating:200 A
Enclosure Type:NEMA 3R
Mounting Type:Flush Surface
Number of Circuits:16
Number of Phases:1
Number of Poles:24
Number Of Spaces:8
Voltage Rating:120/240 V
Features
Optimized knockouts - optimized knockout locations for additional access, easier to remove
Smooth case edges - providing a more professional look and feel
2/0 lug- easily removable and can be installed in any location on the neutral bar
Inboard neutral - increases gutter space to allow for professional installation of conductors
Common drive types (BR)- minimizes number of tools required for installation as the neutral bar and BR breaker screws will share a common drive type Backed out neutral screws - allows for quick connection of neutral and ground conductors
Plug-on neutral (PON) - eliminates the pigtail connection providing time and labor savings
Embossed circuit numbers-durable circuit numbering with added marking for twin breakers
Keyhole hanging feature - ease of cover installation
Rigid cover spine provides strength when twist outs are removed
View Details
|
6908016 |
Eaton BRP08B200RF Load Center, 24-Pole, 200 A, 8-Space, 16-Circuit, Main Breaker, Plug-On Neutral, N |
1 |
199.99 |
/ EA |
BRP08B200RF |
|
|

Square D QO QO612L100RBCP Load Center, 100 A, 6 -Space, 12 -Circuit, Main Lug, NEMA 3R Enclosure, Pl
PRODUCT OVERVIEW
Outdoor main lug load center, 100 A, 6 space 12 circuit. NEMA type 3R enclosure with a rainproof cover. Copper bus bar, accommodates standard QO or QO tandem circuit breakers. ANSI certified and UL listed.
Product Details
Breaker/ Load Center Type:Main Lug
Bus Bar Material:Aluminum
Cable Size:8 to 1 AWG
Color:Gray
Cover/ Lid Type:Surface
Current Rating:100 A
Enclosure Type:NEMA 3R
Finish:Baked Enamel
Interrupt Rating:10 kA
Mounting Type:Plug
Number of Circuits:12
Number of Phases:1
Number Of Spaces:6
Voltage Rating:120/240 V
Wiring Configuration:3-Wire
Features
Indoor and outdoor versions
Separate flush or surface mount covers
Exclusive shielded copper bus features electro tin plated copper bus bars sandwiched between two rugged polymer shields to insulate and secure the interior
Straight-in mains wiring and uniform termination lugs help minimize service cable bends, cutting waste and saving installation time
Convertible mains allow fast field conversion between main breaker and main lugs to meet changing job requirements
QO three-phase main circuit breaker panels can be field upgraded to provide 100 kA short circuit current ratings
Single, captive interior mounting screw can't be lost. Interior mounts quickly and can easily be removed during rough-in for paint or theft protection
Split branch neutral with up to 50% more terminations than UL requirement - simplifies wiring and reduces clutter
Indoor enclosures designed to rotate 180 deg to accommodate top or bottom service entrance feed, saving expensive service cable
Combination slot/square-drive neutral, ground and cover screw accommodate both standard flat blade screwdrivers and square-head drivers
View Details
|
6925945 |
Square D QO QO612L100RBCP Load Center, 100 A, 6 -Space, 12 -Circuit, Main Lug, NEMA 3R Enclosure, Pl |
2 |
69.99 |
/ EA |
QO612L100RBCP |
|
|

Square D HOM4080M200PC Load Center, 80 -Pole, 200 A, 40 -Space, Plug-On Neutral, NEMA 1 Enclosure
PRODUCT OVERVIEW
Built with a plated, aluminum bus bar. Main breaker installed. UL listed.
Product Details
Breaker/ Load Center Type:Plug-On Neutral
Bus Bar Material:Aluminum
Cable Size:4 AWG
Cover/ Lid Type:Flush
Current Rating:200 A
Enclosure Type:NEMA 1
Includes:PK15GTAL Ground Bar Combination Flush/Surface Cover
Interrupt Rating:22 kA
Mounting Type:Flush Surface
Number of Phases:1
Number of Poles:80
Number Of Spaces:40
Voltage Rating:120/240 V
Wiring Configuration:3-Wire
View Details
|
6994255 |
Square D HOM4080M200PC Load Center, 80 -Pole, 200 A, 40 -Space, Plug-On Neutral, NEMA 1 Enclosure |
1 |
249.99 |
/ EA |
HOM4080M200PC |
|
|

Square D HOM2040M100PC Load Center, 40 -Pole, 100 A, 20 -Space, Plug-On Neutral, NEMA 1 Enclosure
PRODUCT OVERVIEW
Built with a plated, aluminum bus bar. Main breaker installed. UL listed.
Product Details
Breaker/ Load Center Type:Plug-On Neutral
Bus Bar Material:Aluminum
Cable Size:6 to 1 AWG
Cover/ Lid Type:Flush
Current Rating:100 A
Enclosure Type:NEMA 1
Includes:PK15GTAL Ground Bar Combination Flush/Surface Cover
Interrupt Rating:22 kA
Mounting Type:Flush Surface
Number of Phases:1
Number of Poles:40
Number Of Spaces:20
Voltage Rating:120/240 V
Wiring Configuration:3-Wire
View Details
|
6994263 |
Square D HOM2040M100PC Load Center, 40 -Pole, 100 A, 20 -Space, Plug-On Neutral, NEMA 1 Enclosure |
1 |
89.99 |
/ EA |
HOM2040M100PC |
|
|

Square D Homeline HOM816L125PRB Load Center, 125 A, 8-Space, 16-Circuit, Main Lug, NEMA 3R Outdoor E
PRODUCT OVERVIEW
Main lug outdoor load center, 125 A 8 space/16 circuit. Convertible to a main breaker. Single-phase load center. Overhead or underground feed options. Plated aluminum bus bar. UL listed.
Product Details
Breaker/ Load Center Type:Main Lug
Bus Bar Material:Aluminum
Cable Size:6 to 2/0 6 to 1
Color:Gray
Cover/ Lid Type:Surface
Current Rating:125 A
Enclosure Type:NEMA 3R Outdoor
Finish:Baked Enamel
Interrupt Rating:22 kA
Mounting Type:Plug
Number of Circuits:16
Number of Phases:1
Number Of Spaces:8
Voltage Rating:120/240 V
Wiring Configuration:3-Wire
Features
Designed for fast installation, reliability and superior circuit protection Faster installation fewer connections
Saves wire - fully-distributed split neutral bar
Frees gutter space - No pigtails
Easier troubleshooting - time-saver diagnostics provide additional circuit information at the touch of a button
Faster and easier wiring all spaces accept tandems
View Details
|
6994677 |
Square D Homeline HOM816L125PRB Load Center, 125 A, 8-Space, 16-Circuit, Main Lug, NEMA 3R Outdoor E |
2 |
77.99 |
/ EA |
HOM816L125PRB |
|
|

Square D HOM3060M200PRBVP Load Center, 60 -Pole, 200 A, 30 -Space, Plug-On Neutral, NEMA 3R Enclosur
PRODUCT OVERVIEW
Homeline value pack. Plug on neutral. 30 space, 60 circuit. Main breaker Included. 200 A. Rainproof/outdoor. Includes three HOM120 and two HOM230 circuit breakers.
Product Details
Breaker/ Load Center Type:Plug-On Neutral
Bus Bar Material:Aluminum
Cable Size:4 AWG
Cover/ Lid Type:Surface
Current Rating:200 A
Enclosure Type:NEMA 3R
Includes:PK15GTAL Ground Bar and Surface Cover
Interrupt Rating:22 kA
Mounting Type:Flush Surface
Number of Phases:1
Number of Poles:60
Number Of Spaces:30
Voltage Rating:120/240 V
Wiring Configuration:3-Wire
View Details
|
7058563 |
Square D HOM3060M200PRBVP Load Center, 60 -Pole, 200 A, 30 -Space, Plug-On Neutral, NEMA 3R Enclosur |
1 |
249.99 |
/ EA |
HOM3060M200PRB |
|
|

Eaton BRP12L125G Load Center, 125 A, 24-Pole, 12-Space, 24-Circuit, Main Lug, Plug-On Neutral, Type
PRODUCT OVERVIEW
Eaton Load Center, 120/240 VAC, 125 A, Number of Phases: 1, Number of Spaces: 12, Number of Poles: 24, Number of Circuits: 24, Breaker/Load Center Type: Main Lug, Plug-On Neutral, Type BR, Interrupt Rating: 10 kAIC, Cable Size: #6 to 2/0 AWG, Wiring Configuration: 3-Wire, Bus Bar Material: Aluminum, Enclosure Type: NEMA 1, Flush, Surface Mounting, Metal, Includes: Cover
Product Details
Breaker/ Load Center Type:Main Lug Plug-On Neutral Type BR
Bus Bar Material:Aluminum
Cable Size:6 to 2/0 AWG
Current Rating:125 A
Enclosure Type:NEMA 1
Includes:Cover
Interrupt Rating:10 kAIC
Material:Metal
Mounting Type:Flush Surface
Number of Circuits:24
Number of Phases:1
Number of Poles:24
Number Of Spaces:12
Voltage Rating:120/240 VAC
Wiring Configuration:3-Wire
Features
Knockout locations for additional access
Optimized knockouts easier to remove
Smooth case edges provides a more professional look and fee
Top or bottom feed straight-in wiring saves labor and material
One panel for either top or bottom applications
2/0 lug easily removable and can be installed in any location on the neutral bar
Compact design for easier wiring improved wireway access
Provides a clean gutter space
Inboard neutral increases gutter space to allow for the professional installation of conductors
Excellent conductivity and corrosion resistance
View Details
|
7119977 |
Eaton BRP12L125G Load Center, 125 A, 24-Pole, 12-Space, 24-Circuit, Main Lug, Plug-On Neutral, Type |
1 |
57.99 |
/ EA |